Product Description

The EA1504-series is an extremely versatile and reliable series of packer feedthrus, suitable for both mud-line packer installations and deep-set packer installations. This series offers extraordinary flexibility. The feedthru may be installed either above or below the packer. A wide range of cross-over adapters solutions is available, which threading as small as 1.90NU Box or Pin-threads.

This series of cross-over adapter has a minimum diameter of 1.95-inches, and is available made from alloy steel, 410 stainless steel or Monel 400. Cable choices include round cables, flat cables and motor lead extension cables. When supplied with an integrally molded MLE, these systems can be installed without a splice below the packer.

For installations with dual ESPs, this product may be installed using a Y-Adapter, allowing two packer feedthrus to be installed on one packer.
 

Specifications

Environmental: 300°F (149°C), 5000 psi
Electrical: 5000 VAC, 20 to 120Hz. Current ratings of 125A, 140A, or 160A depending on cables.

Features

    Flexible Installation

    Motor Lead Extension Cables

    Optional Y-Adapter



FAQs

Is the bore in the packer required to be straight to install the packer feedthru?

While it is always desirable to have straight through-bores in the packer, this is often difficult. Provided that the angles are not extreme, and there is sufficient room to install a cross-over adapter, it will be possible to push cables through the packer bore, even when it is not straight.
 

Is this series of packer feedthru always supplied with lead-sheathed cable?

No. We try to match the cable coming out of the feedthru to the cable actually being used. For mudline packers, it is common to have non-lead-sheated cable above and below the packer. For deep-set packers, the lower cable is almost always lead-sheathed.

We like to install electrical feedthrus above the packer, but we do not want a splice below the packer. Can we install a feedthru with integral MLE above the packer?

In most cases, no, because it is not possible to pass the MLE pothead connector through the packer from above. The only way that the proposed installation would work is, if the drift diameter through the packer is sufficient to allow the feedthru (and upper cable) to be passed through the packer from below. A special cross-over adapter would need to be supplied which allows the feedthru to be secured above the packer and the cross-over adapter.

Packer Feedthru with Molded Cables on Both Sides


Product Description

The EA1504-series is an extremely versatile and reliable series of packer feedthrus, suitable for both mud-line packer installations and deep-set packer installations. This series offers extraordinary flexibility. The feedthru may be installed either above or below the packer. A wide range of cross-over adapters solutions is available, which threading as small as 1.90NU Box or Pin-threads.

This series of cross-over adapter has a minimum diameter of 1.95-inches, and is available made from alloy steel, 410 stainless steel or Monel 400. Cable choices include round cables, flat cables and motor lead extension cables. When supplied with an integrally molded MLE, these systems can be installed without a splice below the packer.

For installations with dual ESPs, this product may be installed using a Y-Adapter, allowing two packer feedthrus to be installed on one packer.
 
Environmental: 300°F (149°C), 5000 psi
Electrical: 5000 VAC, 20 to 120Hz. Current ratings of 125A, 140A, or 160A depending on cables.
  • Flexible Installation

    Cable on both sides supports easy installation with splicing. Crossover adapters have a wide range of Pin or Box threads allowing for installation above or below the packer.
  • Motor Lead Extension Cables

    Can be integrally molded to the feedthru, allowing installation with no splices below the packer
  • Optional Y-Adapter

    May be installed with optional Y-adapter to drive two ESPs